       KLC1-D (NEW) series AC contactors are suitable for frequency 50/60Hz, rated insulation voltage up to 1000V, rated operation current 9~330A under AC-3 duty. It is mainly used for making/breaking
electric circuits at a long distance & for frequent starting/stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products according with the
standards such as IEC60947-4-1.

SPECIFICATIONS (1)
Rated operational current
Ie max AC-3 (Ue¡Ü440V)
Ie AC-1(0¡Ü60¡æ)
09
12
18
25
32
38
Rated operational voltage
690V
Number of poles
3
3
4
3
3
4
3
Number of poles
220/240V
2.2KW
3KW
4KW
5.5KW
7.5KW
9KW
380/400V
4KW
5.5KW
7.5KW
11KW
15KW
18.5KW
415/440V
4KW
5.5KW
9KW
11KW
15KW
18.5KW
500V
5.5KW
7.5KW
10KW
15KW
18.5KW
18.5KW
660/690V
5.5KW
7.5KW
10KW
15KW
18.5KW
18.5KW
1000V
-
-
-
-
-
-
Auxiliary contacts
Range comprising up to 4 N/C or N/O instantantaneous
up to 1N/O+1N/C time delay and up to 2 N/O protected
contacts and 2screen continuity terminals
Compatible
manual or auto
thermal overload
relays
Class 10A
0.10...10A
0.10...13A
0.10...18A
0.10...32A
0.10...38A
0.10...38A
Class 20
2.5...10A
2.5...13A
2.5...18A
2.5...32A
Suppressor modules
(d.c.and low
consumption
contactors have
built-in suppression
limiting diode as
standard)
Varistor
¡¤
¡¤
.
.
.
.
Diode
.
.
.
.
.
.
RC circuit
.
.
.
.
.
.
Bidirectional peak
.
.
.
.
.
.
Interfaces
Relay
.
.
.
.
.
.
Relay+override function
.
.
.
.
.
.
Solid state
.
.
.
.
.
.
Contactor type
references
¡«or 3P
LC1-D09
LC1-D12
LC1-D18
LC1-D25
LC1-D32
LC1-D38
¡«4-P
-
LC1-D12
-
LC1-D25
LC1-D32
-
-4P
-
LC1-D12
-
LC1-D25
LC1-D32
-
Reversing
contactor
type referenees
¡«3P
LC1-D09
LC1-D12
LC1-D18
LC1-D25
LC1-D32
LC1-D38
-3P
LC1-D09
LC1-D12
LC1-D18
LC1-D25
LC1-D32
LC1-D38
¡«4P
-
LC1-D12
-
LC1-D32
-
-4P
-
LC1-D12
-
LC1-D32
-

SPECIFICATIONS (2)

Rated operational current
Ie max AC-3 (Ue¡Ü440V)
Ie AC-1(0¡Ü60¡æ)
40
50
65
80
95
115
150
60A
80A
125A
200A
Rated operational voltage
1000V on¡«supply, 690V on supply
Number of poles
3
4
3
3
4
3
4
3
3
4
3
Rated operational
power in AC-3
220/240V
11KW
15KW
18.5KW
22KW
25KW
30KW
40KW
380/400V
18.5KW
22KW
30KW
37KW
45KW
35KW
75KW
415/440V
22KW
25/30KW
37KW
45KW
45KW
59KW
80KW
500V
22KW
30KW
37KW
55KW
55KW
75KW
90KW
660/690V
30KW
33KW
37KW
45KW
45KW
80KW
100KW
1000V
22KW
30KW
37KW
45KW
45KW
75KW
90KW
Auxiliary contacts
Compatible
manual or auto
thermal overload
relays
Class 10A
17...50A 17...70A 17...80A 17...104A 17...5104A 60...150A 60...150A
Class 20
17...40A
17...65A
17...70A
17...80A
60...150A
60...150A
Suppressor modules
(d.c.and low
consumption
contactors have
built-in suppression
limiting diode as
standard)
Varistor
.
.
.
.
.
.
.
Diode
.
.
.
.
.
.
.
RC circuit
.
.
.
.
.
.
.
Bidirectional peak
.
.
.
.
.
.
.
Interfaces
Relay
.
.
.
.
.
.
.
Relay+override function
.
.
.
..
.
.
.
Solid state
.
.
.
.
.
.
Contactor type
references
¡«or 3P
LC1D40
LC1-D50
LC1D65
LC1D80
LC1D95
LC1D115
LC1D150
¡«4-P
LC1D40
-
LC1D65
LC1D80
-
LC1D115
-
-4P
LC1D40
-
LC1D65
LC1D80
-
LC1D115
-
Reversing
contactor
type referenees
¡«3P
LC1D40
LC1-D50
LC1D65
LC1D80
LC1D95
LC1D115
LC1D150
-3P
-
-
LC1D50
-
-
-
-
¡«4P
LC1D40
-
-
LC1D80
-
LC1D115
-
-
-4P
-
-
LC1D65
-
-
-