APPLICANTION |
KLC1-D (NEW) series AC contactors are suitable for frequency 50/60Hz, rated insulation voltage up to 1000V, rated operation current 9~330A under AC-3 duty. It is mainly used for making/breaking electric circuits at a long distance & for frequent starting/stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products according with the standards such as IEC60947-4-1.
SPECIFICATIONS (1)
|
Rated operational current Ie max AC-3 (Ue¡Ü440V) Ie AC-1(0¡Ü60¡æ) |
09 |
12 |
18 |
25 |
32 |
38 |
Rated operational voltage |
690V |
Number of poles |
3 |
3 |
4 |
3 |
3 |
4 |
3 |
|
Number of poles |
220/240V |
2.2KW |
3KW |
4KW |
5.5KW |
7.5KW |
9KW |
380/400V |
4KW |
5.5KW |
7.5KW |
11KW |
15KW |
18.5KW |
415/440V |
4KW |
5.5KW |
9KW |
11KW |
15KW |
18.5KW |
500V |
5.5KW |
7.5KW |
10KW |
15KW |
18.5KW |
18.5KW |
660/690V |
5.5KW |
7.5KW |
10KW |
15KW |
18.5KW |
18.5KW |
1000V |
- |
- |
- |
- |
- |
- |
Auxiliary contacts |
Range comprising up to 4 N/C or N/O instantantaneous up to 1N/O+1N/C time delay and up to 2 N/O protected contacts and 2screen continuity terminals |
Compatible manual or auto thermal overload relays |
Class 10A |
0.10...10A |
0.10...13A |
0.10...18A |
0.10...32A |
0.10...38A |
0.10...38A |
Class 20 |
2.5...10A |
2.5...13A |
2.5...18A |
2.5...32A |
|
|
Suppressor modules (d.c.and low consumption contactors have built-in suppression limiting diode as standard) |
Varistor |
¡¤ |
¡¤ |
. |
. |
. |
. |
Diode |
. |
. |
. |
. |
. |
. |
RC circuit |
. |
. |
. |
. |
. |
. |
Bidirectional peak |
. |
. |
. |
. |
. |
. |
Interfaces |
Relay |
. |
. |
. |
. |
. |
. |
Relay+override function |
. |
. |
. |
. |
. |
. |
Solid state |
. |
. |
. |
. |
. |
. |
Contactor type references |
¡«or 3P |
LC1-D09 |
LC1-D12 |
LC1-D18 |
LC1-D25 |
LC1-D32 |
LC1-D38 |
¡«4-P |
- |
LC1-D12 |
- |
LC1-D25 |
LC1-D32 |
- |
-4P |
- |
LC1-D12 |
- |
LC1-D25 |
LC1-D32 |
- |
Reversing contactor type referenees |
¡«3P |
LC1-D09 |
LC1-D12 |
LC1-D18 |
LC1-D25 |
LC1-D32 |
LC1-D38 |
-3P |
LC1-D09 |
LC1-D12 |
LC1-D18 |
LC1-D25 |
LC1-D32 |
LC1-D38 |
¡«4P |
- |
LC1-D12 |
- |
|
|
LC1-D32 |
- |
-4P |
- |
LC1-D12 |
- |
|
|
LC1-D32 |
- |
SPECIFICATIONS (2)
Rated operational current Ie max AC-3 (Ue¡Ü440V) Ie AC-1(0¡Ü60¡æ) |
40 |
50 |
65 |
80 |
95 |
115 |
150 |
60A |
80A |
|
125A |
|
200A |
|
Rated operational voltage |
1000V on¡«supply, 690V on supply |
Number of poles |
3 |
4 |
3 |
3 |
4 |
3 |
4 |
3 |
3 |
4 |
3 |
Rated operational power in AC-3 |
220/240V |
11KW |
15KW |
18.5KW |
22KW |
25KW |
30KW |
40KW |
380/400V |
18.5KW |
22KW |
30KW |
37KW |
45KW |
35KW |
75KW |
415/440V |
22KW |
25/30KW |
37KW |
45KW |
45KW |
59KW |
80KW |
500V |
22KW |
30KW |
37KW |
55KW |
55KW |
75KW |
90KW |
660/690V |
30KW |
33KW |
37KW |
45KW |
45KW |
80KW |
100KW |
1000V |
22KW |
30KW |
37KW |
45KW |
45KW |
75KW |
90KW |
Auxiliary contacts |
|
Compatible manual or auto thermal overload relays |
Class 10A |
17...50A 17...70A 17...80A 17...104A 17...5104A 60...150A 60...150A |
Class 20 |
17...40A |
17...65A |
17...70A |
17...80A |
|
60...150A |
60...150A |
Suppressor modules (d.c.and low consumption contactors have built-in suppression limiting diode as standard) |
Varistor |
. |
. |
. |
. |
. |
. |
. |
Diode |
. |
. |
. |
. |
. |
. |
. |
RC circuit |
. |
. |
. |
. |
. |
. |
. |
Bidirectional peak |
. |
. |
. |
. |
. |
. |
. |
Interfaces |
Relay |
. |
. |
. |
. |
. |
. |
. |
Relay+override function |
. |
. |
. |
.. |
. |
. |
. |
Solid state |
. |
. |
. |
|
. |
. |
. |
Contactor type references |
¡«or 3P |
LC1D40 |
LC1-D50 |
LC1D65 |
LC1D80 |
LC1D95 |
LC1D115 |
LC1D150 |
¡«4-P |
LC1D40 |
- |
LC1D65 |
LC1D80 |
- |
LC1D115 |
- |
-4P |
LC1D40 |
- |
LC1D65 |
LC1D80 |
- |
LC1D115 |
- |
Reversing contactor type referenees |
¡«3P |
LC1D40 |
LC1-D50 |
LC1D65 |
LC1D80 |
LC1D95 |
LC1D115 |
LC1D150 |
-3P |
- |
- |
LC1D50 |
- |
- |
- |
- |
¡«4P |
LC1D40 |
- |
- |
LC1D80 |
- |
LC1D115 - |
- |
-4P |
- |
- |
LC1D65 |
- |
- |
- | | |